AC Sizing
Which AC capacity fits your room.
How it works
Rule of thumb: 150–220 W of cooling per m² of floor (about 20–30 BTU per ft²). Top floor, west sun or large glazing needs more.
Worked example with the defaults
This example is calculated from the page defaults. Change the form to update the live result.
| Room area | 15 m² |
|---|---|
| Ceiling | 2.8 m |
| Exposure | Normal |
| Calculated result | 9,212 BTU/h · 2700 W cooling |
| Equivalent | 1.2 HP / 2.7 kW |
| Common sizes | 9k / 12k / 18k / 24k BTU |
| Per unit area | 180 W |
Sizing assumptions and questions
This quick estimate scales a cooling load by floor area, ceiling height and exposure, then reports BTU/h. It is a screening estimate, not an HVAC load calculation.
Limits and assumptions
- Glazing, solar gain, occupancy, appliances, insulation, humidity and climate can change the required capacity.
- The model starts at 180 W/m² and applies a 15% uplift for the selected west-facing/top-floor option.
- Compare the unit’s rated cooling capacity and efficiency; room area alone does not size a system.
Common questions
What does the Chinese “pi” rating mean?
It is a local rough size label. The Chinese page converts estimated cooling watts using about 2,324 W per pi; it is not electrical input power.
Why does this page use BTU/h?
BTU/h is a common cooling-capacity unit in English-language markets; the estimate starts from watts and converts the result.
Is the west-facing adjustment enough for a hot attic room?
Not necessarily. The 15% uplift is only a rough adjustment; a large sunny room may need an on-site load assessment.